Search
Wish list
Region
Region (de)
Products
Company
Focus on
Contact
de  en  pl  fr  hr  nl  hu  it  sv  sl  cn  es
Press and drag mouse button

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Single wall insert with plug-in socket

for setting in concrete and connecting smooth cable ducts

HSI150 GSM

Für den beidseitigen gas- und wasserdichten Anschluss von Systemabdichtungen für Kabel und Kabelschutzrohre und eine maximale Flexibilität bei der späteren Nutzung.

Polymer flange

for retrofit dowelling

HSI150 DFK

For retrofit dowelling via core drill holes or for screwing onto housings. Used for the gastight and watertight connection of system seals for cables and cable ducts.

Double wall insert

for setting in concrete

HSI90 K2/X

For the gastight and watertight connection on both sides of system covers for cables and cable ducts and maximum flexibility for subsequent use.

System cover

cable seal with hot shrink-fit method

HSI150 D WS

For use in wall insert and plastic flange HSI150. The thermal sleeves support a wide area of application, they are shrunk onto the cables by means of the application of heat from the system cover socket. Empty system cover sockets can be sealed with blind plugs.

Closing cover

for empty wall inserts and plastic flanges

HSI150 DT

For pressure-tight sealing of wall inserts that are not in use and plastic flange of the HSI150 system.

Insulated earthing entry

HEA IS

Specifically for station construction. Installed during formwork work. Earthing connections to the building can be made with the thread on both sides in the electrically isolated conductor core.

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Split system cover

for retrofit sealing

HSI150 DG

For use in wall insert and polymer flange HSI150. Split design for sealing new cables to be installed or cables that have already been laid.

Individual press seal

for micro pipes and empty conduits

HRD150 b60 A2/EPDM55

Individual press seal in a closed design to seal micro pipes or empty conduits.

Site power supply entry

for secondary substations

BD

Zur temporären Stromversorgung bzw. Notversorgung von Transformatorenstationen. Mit der Baustromdurchführung können Kabel während Baumaßnahmen oberirdisch in die Station eingeführt werden. Die Stationstüren können somit geschlossen werden.

SEGMENTO

Segments for installation in HSI150 S3 system cover

SEG

For particularly gentle sealing of micropipes and control lines.

 Close

Earthings

HEA earthing connections are available for delivery as entries or earthing fixed points in various designs to meet prevailing requirements. Both solutions for installation in concrete walls flush with shuttering and solutions for retrofitting in drill holes are available. Hauff-Technik offers an insulated earthing entry specifically for station construction. The earthing connections, which are manufactured in stainless steel to the highest quality standards, maintain their function throughout their service life. They are used for protective earthing, functional earthing, operational earthing and lightning protection earthing, for example.

Earthings